45 mil
The thinnest common sheet. Lowest cost; fine for short-term holds or buildings with a near-term plan to change.
Roofing systems · TPO & PVC
TPO and PVC are white single-ply membranes with heat-welded seams, and they cover a large share of commercial roofs in New York. They look alike on the roof but behave differently over a kitchen exhaust or a chemical vent. Here is how we choose, install and repair them.
The basics
A single-ply roof is one layer of flexible membrane over insulation, instead of the several asphalt plies of a built-up or modified bitumen roof. TPO (thermoplastic polyolefin) and PVC (polyvinyl chloride) are the two thermoplastic kinds: their seams are melted together with hot air, so the joints become the same material as the sheet. EPDM, the third single-ply, is rubber and is joined with tapes and adhesives instead.
Both come white as standard, which matters in New York: a white membrane usually meets the city's cool-roof requirement on its own, with no coating needed. Which manufacturer's sheet goes on is decided per job and written into the scope.
TPO or PVC
| Building | Usual pick | Why |
|---|---|---|
| Warehouse, distribution or big-box store | TPO | Large open roof, few penetrations; TPO covers it at a lower material cost |
| Restaurant, bakery or food processing | PVC | Grease and fats from kitchen exhaust attack many membranes; PVC makers and roofers treat PVC as the standard here |
| Retail or office with many rooftop units | Either, plus walkway pads | Service traffic causes most punctures; pads and protection around units matter more than the membrane |
| Labs, workshops, roofs near chemical vents | PVC | Better resistance to oils and many chemicals |
| Budget-led recover over a sound roof | TPO | Often the most economical single-ply option where the code allows a recover |
Manufacturers of PVC, such as Siplast and Holcim Elevate, recommend PVC over kitchens and restaurants. Where only one area of a roof sees grease, a PVC section or a grease containment system at the exhaust fan can be combined with TPO elsewhere.
Specification
The thinnest common sheet. Lowest cost; fine for short-term holds or buildings with a near-term plan to change.
The everyday commercial choice. More material above the reinforcing scrim, so it tolerates weathering and foot traffic better.
For long ownership, heavy traffic or long warranty terms. Carlisle, for example, ties its 25- and 30-year system warranties to its thicker sheets.
Johns Manville makes its TPO in 45, 60 and 80 mil, and lists guarantees of up to 20 years on its 60-mil self-adhered sheet. Which term applies depends on the system and the installer.
| Method | How it works | Trade-offs |
|---|---|---|
| Mechanically fastened | Plates and screws through the insulation into the deck, sheets welded over the plates | Fast and economical; needs a deck that holds screws (steel or wood); sheets can flutter in high wind if poorly detailed |
| Fully adhered | Membrane glued to the insulation board | Smooth, quiet, strong in wind; adhesive smell during work, so fresh-air intakes are planned around |
| Induction-welded | Plates fastened under the membrane, then bonded to it from above with an induction tool | No fasteners through the sheet seams; good wind performance on long spans |
The choice depends on the deck (steel, wood or concrete), wind exposure at the roof's height and location, and how the building is used during the work.
Workmanship
A heat-welded seam is only as good as its temperature, speed and pressure. Too cold and it peels; too hot and it scorches. Trade-press investigations of failed TPO roofs keep finding the same thing: voids in welds that were never tested. That is why every seam should be probed along its full length the day it is welded, and any cold spot re-welded before the crew leaves. Ask any installer how they test seams; the answer tells you a lot.
On a membrane in good condition, a puncture or open seam is cleaned, prepared and covered with a welded patch of the same material. Older sheets are harder: weathered TPO can stop accepting a weld, and patches then fail at their edges. When test welds no longer hold, repairing that area means replacing a section rather than patching it. Before any patch goes on, the leak itself has to be traced to its entry point; see commercial roof repair for how that works.
New York City's Building Code (§1504.9) sets a minimum solar reflectance of 0.70 with thermal emittance of 0.75, or a Solar Reflectance Index of 82, for low-slope roofs. White TPO and PVC normally clear it. Products are rated by the Cool Roof Rating Council, which lists an "initial" value for new material and a "3-year aged" value after weathering; the aged figure is the realistic one for a city roof. If the roof is a full replacement, also check whether Local Laws 92 and 94 require solar or a green roof. The full rule, including when a reroof is too small to be caught, is in our NYC cool roof guide.
Manufacturers offer system warranties on single-ply roofs, with length tied to thickness and to the installer's approval. Ask each bidder whose warranty is on offer and what it requires. On new roofs we give a 2-year labor warranty, plus a 20-year manufacturer warranty on materials.
Price depends on roof size, tear-off or recover, insulation thickness, membrane type and thickness, attachment method, and the number of curbs, drains and penetrations to detail. PVC costs more per square foot than TPO. We price after a survey, in writing. Beyond the roof itself, the site changes the figure too: the building's location, how materials get up to the roof, how debris comes down, the space around the building and the roof's condition.
PVC, at least around the kitchen exhaust. Grease carried out by the exhaust fan settles on the roof, and PVC holds up to it far better. Adding grease containment at the fan helps any membrane.
If you will own the building for a long time, the roof gets regular foot traffic, or you want the longest warranty term, 80 mil is usually worth it. For most other commercial roofs, 60 mil is the sensible standard.
Often, if the sheet is cleaned and prepared properly. We test-weld first. If the old membrane will not take a weld, the honest answer is section replacement, not a patch that peels.
TPO is one kind of single-ply. PVC and EPDM are the others. For how the choice is made on a commercial building, see our systems comparison guide; for a side-by-side of the materials themselves, our sister site's flat roof comparison.
We will tell you what we see and when we can be on the roof. Estimates are free and come in writing.